Designing Museum Storage and Archives: Receiving, Environmental Control, and Research Access

Most of a museum’s collection is never on display. Surveys of the sector consistently find that the majority of the objects and records held by museums, galleries, archives and libraries spend their lives in storage, and that a large share of those stores are full, difficult to work in, or no longer suited to the material they hold (ICCROM–UNESCO, 2011; ICOM, 2024). Storage is therefore not a leftover space behind the galleries. It is where the collection actually exists, where it is preserved or slowly lost, and where most research and documentation take place. This article sets out how storage and archive buildings are planned as working environments: how material arrives and is checked, how the internal climate and air are controlled, how objects are shelved and handled, and how researchers reach the collection without putting it at risk.
What storage has to do
A collection store has four jobs that pull in different directions. It must keep objects physically stable over decades; it must keep them findable and documented; it must let staff and researchers reach them; and it must protect them from fire, water, theft and pests. Each of these can be optimised on its own, but the design problem is their intersection. A sealed, climate-tight room is stable yet hard to enter; dense shelving saves floor area but slows retrieval; generous study access raises the risk of handling damage. Competent storage design is the negotiation of these trade-offs for one specific collection, not the application of a single template.
Receiving, quarantine and documentation
Material enters a collection through a sequence that begins outside the store. A receiving or loading area sized for the largest expected crate, with level access and room to open and inspect, prevents damage at the most vulnerable moment in an object’s life. New or returning objects are not taken straight to the shelves. They pass through an isolation or quarantine room where they are examined for pest activity and mould before they can contaminate the wider collection. Integrated pest management — monitoring, inspection and, where necessary, low-oxygen or freezing treatment rather than routine chemical fumigation — has become standard practice in the sector (Pinniger, 2015), and the building has to provide the rooms and the clean, separated routes that make it workable.
Documentation runs in parallel. An object that cannot be located or identified is, in practice, lost. Space for registration, marking, photography and condition recording belongs within the storage suite rather than as an afterthought, and the layout should let an object travel from receiving to documentation to its storage location without crossing dirty routes or public circulation.
The conservation environment
The most debated aspect of storage design is the control of temperature and relative humidity (RH). Unstable humidity drives the mechanical damage that cracks panel paintings, warps veneers and delaminates layered objects, while sustained high humidity brings mould and corrosion, and very low humidity embrittles organic material. For much of the twentieth century the sector worked to a single tight target, often cited as roughly 50% RH with narrow tolerances, following Thomson’s influential account of the museum environment (Thomson, 1986).
That rigid target has since been relaxed in favour of graded specifications. The ASHRAE chapter on museums, galleries, archives and libraries sets out types of control — labelled AA, A, B, C and D — that pair an annual average with defined seasonal adjustments and short-term fluctuations, and that state the collection risk each band accepts (ASHRAE, 2023; Canadian Conservation Institute). A precision band might hold a short-term swing to within about ±5% RH, while a lower band tolerates a far wider seasonal drift at a stated, acceptable risk to less sensitive material. The logic of the graded approach is that the right environment depends on what is stored and on the local climate, and that chasing a single number can cost enormous energy for little conservation gain. Reviews of the control debate make the same argument: the aim is to avoid harmful fluctuation and extremes, not to defend an arbitrary set point (Kirby Atkinson, 2014), and national guidance such as the United Kingdom’s PAS 198 frames the task as managing risk across the whole collection rather than meeting a fixed figure (BSI, 2012). Light, immaterial to a gallery’s drama but destructive over time, is simply excluded from a store; air filtration against particulates and gaseous pollutants, and separate provision for cold or frozen storage of photographic and film material, complete the environmental brief.
Storage systems, handling and circulation
How objects sit on the shelf is a building decision as much as a furniture one. Mobile or compact shelving, mounted on tracks so that aisles open only when needed, can roughly double capacity within the same footprint, but it adds floor loading, demands a flat and strong structure, and leaves only one aisle reachable at a time — a constraint on both retrieval and escape. Different materials need different systems: rolled textiles and oversize paintings on hanging screens, works on paper in flat files, heavy stone or metal on low racking reachable by trolley. The design has to anticipate the physical range of the collection, including the few very large or very heavy items that set the dimensions of doors, lifts and aisles.
Handling is where most storage damage actually happens, so the routes matter. Aisle and door widths, the turning space for trolleys, the location and size of lifts, and the avoidance of steps and thresholds together decide whether an object can be moved safely or must be lifted and carried. A store planned without a continuous, level, adequately sized path from shelf to study room to exit will see that path improvised, and improvisation is where things are dropped.
Research and collection access
Storage that no one can use defeats the purpose of keeping the collection. Access is designed as a graded sequence that keeps the researcher and the collection separate for as long as possible. A study or reading room, supervised and fitted for careful examination, is where material is consulted; objects are retrieved to it rather than researchers being admitted to the stacks. Some institutions add visible or open storage, where parts of the collection are shelved behind glass so visitors can grasp the scale of what is held without handling it. Digitisation changes the pattern further: a well-catalogued, photographed collection can answer many enquiries without the object moving at all, which is itself a conservation measure. The building supports this with space for imaging, for data, and for the staff who mediate between the store and its users.
Security, fire and resilience
Because a store concentrates irreplaceable material in one place, its protective systems are designed for consequence, not only probability. Fire detection and suppression are chosen to limit water damage as well as fire — mist or gaseous systems where appropriate — and the store is kept clear of the building’s water risks, since a burst pipe or a flooded basement has ruined more collections than fire. Compartmentation, controlled access, and environmental monitoring that raises an alarm on failure are the quiet infrastructure that lets the other decisions hold over time.
Limitations
This article describes principles, not a specification. The correct environmental band, shelving system and access model depend on the specific collection, its condition, the climate and the institution’s resources, and sound decisions require conservators, collection managers and engineers working together on the actual holdings. The environmental figures cited illustrate the graded approach and are not design set points. Much published guidance reflects the resources of large, well-funded institutions; smaller museums often work with adapted buildings and limited budgets, where the realistic goal is reducing the worst risks rather than meeting an ideal. Finally, the standards and the climate-control debate continue to evolve, particularly under pressure to cut the energy that tight control consumes.
ArchUp reading
Storage is the part of a museum where the gap between image and operation is widest. A new building is judged by its galleries, yet most of its collection, and most of the real conservation work, lives in rooms the visitor never sees — and those rooms are often first to be cut when budgets tighten. The shift from a single humidity target to graded, risk-based control is a healthy correction, but it places more judgement on the institution and can be misused to present poor conditions as merely a lower band. The more durable lesson is that storage rewards sober, specific thinking — about this collection, this climate, these staff — over the transfer of a standard figure from one project to the next. A store designed around how objects actually arrive, rest and are retrieved will outlast one designed around a number.
References
- ASHRAE (2023). Museums, Galleries, Archives, and Libraries, Chapter 24, ASHRAE Handbook—HVAC Applications. American Society of Heating, Refrigerating and Air-Conditioning Engineers.
- BSI (2012). PAS 198:2012 — Specification for managing environmental conditions for cultural collections. British Standards Institution.
- BSI (2017). BS 4971:2017 — Conservation and care of archive and library collections. British Standards Institution.
- Canadian Conservation Institute. Climate guidelines: ASHRAE types of control (S. Michalski). Government of Canada.
- Florescu, O., Ichim, P., Sfîcă, L., Kadhim-Abid, A., Sandu, I. & Nănescu, M. (2022). Risk assessment of artifact degradation in a museum, based on indoor climate monitoring. Applied Sciences, 12(7), 3313. DOI: 10.3390/app12073313
- ICCROM–UNESCO (2011). International Storage Survey. International Centre for the Study of the Preservation and Restoration of Cultural Property.
- ICOM (2024). Museum Storage around the World. International Council of Museums.
- Kirby Atkinson, J. (2014). Environmental conditions for the safeguarding of collections: a background to the current debate on the control of relative humidity and temperature. Studies in Conservation, 59(4), 205–212. DOI: 10.1179/2047058414Y.0000000141
- Pinniger, D. (2015). Integrated Pest Management in Cultural Heritage. Archetype Publications.
- Thomson, G. (1986). The Museum Environment (2nd ed.). Butterworth-Heinemann.